Filter Media

Industrial Water Cartridge Filter AquaLine

Industrial water cartridge filter AquaLine 1-20 micron for RO pretreatment and process duty. Match flow, differential pressure, 80CF housing, fluid, and stock.

Pentair AquaLine industrial water cartridge filter

Pentair AquaLine industrial water cartridge filters are selected to retain particles before RO, polishing, and high-flow liquid-process duties. Select ALN01, ALN05, ALN10, or ALN20 from the 1, 5, 10, or 20 micron target, then match flow, differential pressure, temperature, fluid, and the AquaLine 80CF housing.

PT Watermart Perkasa supplies Pentair AquaLine high-flow cartridge filters through water.co.id for water-treatment systems in Indonesia. Design data should be checked as one package, not from micron rating alone.

Updated 5 August 2026: industrial water cartridge-filter intent, sizing data, and AquaLine procurement inputs were clarified.

Nominal filtration targetElement modelNominal dimensionsDatasheet operating limit
1 micronALN01-60B60-inch length; 6.75-inch ODChange-out at 25-30 PSID subject to process limits; maximum 54.4°C
5 micronALN05-60B60-inch length; 6.75-inch ODChange-out at 25-30 PSID subject to process limits; maximum 54.4°C
10 micronALN10-60B60-inch length; 6.75-inch ODChange-out at 25-30 PSID subject to process limits; maximum 54.4°C
20 micronALN20-60B60-inch length; 6.75-inch ODChange-out at 25-30 PSID subject to process limits; maximum 54.4°C

The figures in this table follow the linked Pentair datasheets, checked on 17 July 2026. Request the latest revision and the differential-pressure curve for the design fluid and flow before procurement. Provide normal and peak flow, particle target, solids load, temperature, fluid chemistry, allowable pressure, installation space, and redundancy needs through Watermart’s contact form. See the cartridge-filter category, cartridge-filter housings, and RO pretreatment components.

Sizing data for an industrial water cartridge filter

Industrial water cartridge-filter sizing starts with peak flow and the pressure-drop curve for the cartridge model being installed. For RO, polishing, or process service, the buyer should define the clean and dirty differential-pressure limits, housings per train, closure-opening clearance, and isolation method for element change-out.

Project dataEffect on AquaLine selection
Normal and peak flowDetermines the number of 80CF housings or parallel trains
Solids load and micron targetSets the ALN01, ALN05, ALN10, or ALN20 choice
Allowed differential pressureSets the margin before alarm or cartridge change-out
Fluid quality, temperature, and chemistryChecks PolyForm, Buna-N, PVC core, and FRP housing compatibility
Operating schedule and shutdown limitDetermines duty/standby needs, gauges, isolation valves, and cartridge stock

AquaLine element and 80CF housing technical documents

What does a Pentair AquaLine cartridge filter do?

Pentair AquaLine cartridge filters separate particles from liquid streams in prefiltration, guard-filtration, and final-filtration duties. The elements use polypropylene PolyForm media, a single-open-end configuration, and outside-in flow. The AquaLine 80CF FRP housing accepts one 6.75-inch-diameter element and uses a quick-opening closure for tool-free access.

Key characteristics of AquaLine cartridge filters

  • High Flow Capability: Pentair lists modular AquaLine system configurations from 50 to 10,000 gpm; the housing count must be sized from the pressure curve and design flow.
  • Advanced PolyForm Media: PolyForm media is 100% polypropylene micro-fibers with Locked Pore structure for high filtration efficiency and maximum durability.
  • Tool-Free Quick Change-Out: The quick-opening closure gives access to the element without tools.
  • Chemical & Corrosion Resistance: Compatible with corrosion-resistant FRP housing, suitable for aggressive environments and seawater applications.
  • Flexible Configuration: Single open end, outside-in flow design, easy to integrate in new or retrofit systems.

AquaLine filter-cartridge technical specifications

AquaLine ALN01-60B cartridge-filter element

SpecificationDetails
Element TypeAQUAline fluid process element
Separation MediaPolyForm media (100% polypropylene micro-fibers, cross-linked in a Locked Pore Structure)
Media Efficiency1 Micron (Nominal)
End CapsNylon
SealsBuna-N O-Rings
ComponentsPVC Core
ConfigurationSingle Open End; Outside-in Flowing
DimensionsLength: 60” (152.4 cm); OD: 6.75” (17.15 cm)
Recommended Change-out25-30 PSID (based on process limits)
Max Operating Temp130ºF (54.4ºC); for higher, contact Pentair

Download the AquaLine ALN01-60B datasheet

AquaLine ALN05-60B cartridge-filter element

ParametersDetails
Element TypeAquaLine Fluid Process Element
Separation MediaProprietary PolyForm: 100% polypropylene micro-fibers, locked-pore structure
Media Efficiency5 micron (Nominal)
End CapsNylon
SealsBuna-N O-Rings
ComponentsPVC Core
ConfigurationSingle Open End; Outside-In Flowing
DimensionsNominal Length: 60” (152.4 cm); Nominal O.D.: 6.75” (17.15 cm)
Ratings25-30 PSID recommended change-out (per process); Max Operating Temp: 130°F (54.4°C)

Download the AquaLine ALN05-60B datasheet

AquaLine ALN10-60B cartridge-filter element

FeatureSpecification
Element TypeAQUALINE fluid process element
Separation MediaProprietary 100% polypropylene PolyForm micro-fiber, locked pore structure
Media Efficiency10 micron (Nominal)
End CapsNylon
SealsBuna-N O-Rings
ComponentsPVC core
ConfigurationSingle Open End; Outside-in Flowing
DimensionsLength: 60” (152.4 cm); Nominal O.D.: 6.75” (17.15 cm)
Recommended Change-Out25-30 PSID (based on process limits)
Max Operating Temperature130°F (54.4°C)

Download the AquaLine ALN10-60B datasheet

AquaLine ALN20-60B cartridge-filter element

FeatureSpecification
Element TypeAQUALINE Fluid Process element
Separation MediaProprietary PolyForm media (100% polypropylene microfibers, locked pore structure)
Media Efficiency20 micron (Nominal)
End CapsNylon
SealsBuna N-O Rings
ComponentsPVC core
ConfigurationSingle Open End; Outside-in Flowing
DimensionsLength: 60” (152.4 cm), Nominal O.D.: 6.75” (17.15 cm)
Recommended Exchange25-30 PSID (Process limit dependent)
Maximum Temp130°F (54.4°C)

Download the AquaLine ALN20-60B datasheet

AquaLine Cartridge Filter Housing 80CF15-60

To support AquaLine cartridge filters, PT Watermart Perkasa also supplies the FRP AquaLine 80CF Cartridge Filter Housing for high-flow reverse osmosis (RO), seawater pretreatment, and industrial-process duties. The housing can be mounted horizontally on a skid or vertically and arranged in a modular layout for the design capacity.

Model No.Drawing No.Design/Operating PressureMax. Operating TemperatureQualification PressureElement Length
AQUALINE 80CF15-6017028150 PSI / 10 Bar140°F / 60°C900 PSI / 62 Bar60”

Download the AquaLine 80CF15-60 housing datasheet

AquaLine 80CF housing features

  • Quick Opening Closure Mechanism: quick access without tools for cartridge replacement.
  • Corrosion Resistant FRP Construction: resistant to aggressive environments and seawater.
  • Stackable & Modular Design: can be integrated in parallel for greater capacity.
  • Sea Water Compatibility: Super Duplex FC port for desalination applications.
  • Easy Maintenance: mirror-finish inner surface and UV-resistant polyurethane exterior coating.

AquaLine cartridge-filter and housing applications

  • Filtration of industrial process water and wastewater
  • Pre-filtration and guard filtration in reverse osmosis (RO) systems
  • Food & beverage production
  • Pharmaceutical and ultrapure water treatment
  • Modular plant upgrades and retrofits of existing systems
  • Seawater desalination and brackish water applications

Installation Requirements & Compatibility

  • Match the element with an AquaLine 80CF FRP housing suitable for the process pressure, temperature, ports, and fluid.
  • Each housing accepts one AquaLine element with a single-open-end, outside-in flow orientation.
  • Ensure use of Buna-N O-Rings per process chemical compatibility.
  • For temperature applications above 130°F (54.4°C), consult PT Watermart Perkasa.
  • Modular system: can be integrated with multi-media bed, adsorption, neutralization, and membrane modules.

AquaLine product configuration summary

  • High filtration efficiency with PolyForm media
  • Fast cartridge replacement without tools
  • Corrosion and chemical resistant construction
  • Modular design, easy to upgrade or retrofit
  • Various micron ratings available: 1, 5, 10, 20 microns

What data is needed for an AquaLine quotation?

To request a quotation for Pentair AquaLine cartridge filters and the AquaLine 80CF Housing, identify the initial model and provide the process data. Availability, document revision, port material, and configuration must be confirmed with the quotation.

Ordering Information

  • Model: AquaLine ALN01-60B, ALN05-60B, ALN10-60B, ALN20-60B
  • Housing: AQUALINE 80CF15-60
  • Process data: normal/peak flow, nominal target, temperature, pressure, fluid, solids load, and allowable differential pressure

Pentair AquaLine selection FAQ

Who supplies Pentair AquaLine cartridge filters in Indonesia?

PT Watermart Perkasa supplies Pentair AquaLine ALN01, ALN05, ALN10, and ALN20 elements and the AquaLine 80CF housing through water.co.id for water-treatment projects in Indonesia. Confirm the model, ports, current documents, and availability when requesting a quotation.

Is a 1-micron element always more suitable than 5, 10, or 20 microns?

No. A finer rating can increase differential pressure and shorten the change-out cycle when the solids load is high. Select the nominal rating from the process-protection target, particle distribution, feed quality, pressure curve, and acceptable pressure-drop limit.

When should an AquaLine element be changed?

The element datasheets recommend change-out at 25-30 PSID, subject to process limits. Set the actual trigger from clean differential pressure, process limits, filtrate quality, and the operating trend; do not apply one calendar interval to every feedwater condition.

Contact Us

For technical consultation, a quotation, or more information about Pentair AquaLine cartridge filters and the AquaLine Cartridge Filter Housing, contact PT Watermart Perkasa by WhatsApp, email, or the contact form.

WhatsApp