Short answer: select a Pentair Autotrol valve after defining whether the vessel is a filter or softener, service flow, required backwash, tank diameter, connections, and regeneration method. Time-clock controls follow a schedule; metered-demand controls regenerate a softener from measured water use. Treat the valve, timer, injector, and cycle sequence as one matched package.
PT Watermart Perkasa, operating through water.co.id, supplies Pentair Autotrol valves, timers, and related water-treatment components in Indonesia. Buyers can match Autotrol with FRP tanks, DIONIX ion-exchange resin, filter media, and water-softening systems using actual water and hydraulic data.
Updated 29 July 2026. The approved model data sheet and manual remain controlling.
Which Pentair Autotrol valve fits a filter or softener?
| System need | Family to evaluate | Data to prepare |
|---|---|---|
| Single-tank media filter | Autotrol 363 or a Performa filter configuration | Service flow, backwash flow and duration, tank diameter, media, connections |
| Single-tank softener | Autotrol 255, 268, or 368 with a compatible controller | Hardness, resin capacity, peak flow, salt dose, injector, regeneration sequence |
| Scheduled operation | Compatible 740/742 or time-clock controller | Regeneration day and time, available backwash flow, risk of delayed regeneration |
| Usage-based regeneration | Compatible 760/762 or metered-demand controller | Meter, programmed capacity, reserve, minimum-to-peak demand pattern |
| Commercial or multi-tank system | Performa 273/278, Magnum, or Logix 764 as configured | Duty/standby or parallel mode, peak flow, backwash, interlocks, service clearance |
The Autotrol 255/Performa manual for 742/762 controls and Autotrol 363 automatic-filter-valve data sheet show that valve body, controller, injector, flow control, and tank size are interdependent. Do not order from a timer number alone; verify the existing valve body, voltage, harness, plumbing, and cycle program.
Pentair Autotrol Product Options for Water Treatment
1. Pentair Autotrol 460i & 460TC Control System
The Autotrol 460i (demand/metered) and 460TC (time clock) electronic control systems offer microprocessor-based softener regeneration management. The 460i model activates regeneration based on actual water usage, while the 460TC uses a time clock (1-30 days). Both feature NOVRAM nonvolatile memory that preserves cycle and water usage data even during power outages.
- Easy setup with jumpers and push-buttons
- Salt setting range: 12-60 kg (see setting table in manual)
- Hardness setting: 1-99 GPG (460i only)
- Manual regeneration via push-button
- Display flow indicator and timer status
Advantages: Efficient use of salt and water, automatic operation, and compatibility with various resin tank sizes (0.5-2.5 cu ft).
Download 1017948-autotrol-460i-460tc-manual.pdf
2. Pentair Autotrol Magnum Control Valve
This high-performance valve made from fiber-reinforced polymer is designed for large-scale softener and filtration applications (industrial, commercial, and municipal). Key features include Duraflow flapper for long-lasting sealing, optical sensor for cycle positioning, and flow capabilities up to 76 GPM (service) and 89 GPM (backwash).
- Adjustable 3- or 5-cycle operation
- Non-volatile memory and supercapacitor
- Single/multi-tank, top/side mount configurations
Download 1017972-autotrol-magnum-spec-sheet.pdf
3. Autotrol Performa Valve with 400 Series Control
The Performa control system with 400 Series Controller (440i, 460i, 460TC) offers NSF/ANSI 44 & 61 compliance, programmable regeneration cycles, and pressure-resistant construction up to 125 psi. Suitable for residential and light commercial applications.
- Brine refill control: 1-10 lbs or 3-19 lbs salt
- Injector sizes: 4 coded nozzles (A, B, C, D)
- Multiple electrical rating options
Download 1222945-autotrol-performa-400-service-manual.pdf
4. Autotrol 255 & Performa Series Valves (263, 268, 268 FA) with 742/762 Control
This valve supports time-clock (742) and metered-demand (762) control with NSF/ANSI 44, 61, and 372 certifications. Features self-test, easy configuration, and compatibility with various tank sizes.
- Rated service flow up to 11 GPM
- Salt dose and capacity can be adjusted as needed
- WQA certified models available
Download 3000440-autotrol-255-performa-manual.pdf
5. 742/762 Control Performa Cv Series Valves
This valve offers the flexibility of time clock (742) and metered-demand (762) modes with LCD interface, self-test, and compatibility with various valve bodies (263, 268, 273, 278, 293, 298). Suitable for both softener and filter applications.
Download 3001093-autotrol-742-762-manual.pdf
6. Logix Retrofit Kit for 255 Valve
This upgrade kit allows the conversion of Autotrol 255 valves into Logix Control automation systems. It features optical sensors, motor drives, refill flow control, and injectors according to tank configuration.
Download 3002943-255-logix-retrofit-kit.pdf
7. Logix 764 Controller for Model 255
Advanced controller for Twin Alternating, Twin Parallel, Single with Remote Start, and Multi-Single Tank Lockout configurations. LCD display, keypad interface, and UL/CE compliance make the Logix 764 a top choice for industrial and commercial applications.
Download 3019624-autotrol-logix-764-manual.pdf
8. Logix 764 Operation Manual for Magnum IT
This manual covers the installation, operation, and maintenance of the Logix 764 for Magnum IT 293/298 valves. It supports multi-mode (Twin Alternating, Twin Parallel, Single Remote Start), programmable, and LCD interface.
Download 3020015-autotrol-logix-764-owners-manual.pdf
9. Autotrol 273 & 278 Commercial Performance Control Valves
Commercial valves with fiber-reinforced polymer body, Duraflow flapper, and optical sensor. Supports flow up to 25 GPM (service) and 20 GPM (backwash), and programmable 3/5 cycle control.
Download 4000570-autotrol-273-278-spec-sheet.pdf
10. Autotrol 368 Control Valve
Valve for single-tank softener with double backwash, optical sensor, and flow up to 16.6 GPM. Suitable for residential and light commercial applications.
Download 4002013-auotrol-368-spec-sheet.pdf
11. Autotrol 363 Automatic Filter Valve
Automatic filter valve for single tanks, fiber-reinforced polymer body, Duraflow flapper, and flow up to 21 GPM. Supports tanks up to 36” diameter.
Download 4002833-autotrol-363-spec-sheet.pdf
12. Autotrol 460i Timer
Electronic timer with two digit LED display, flow indication, and memory retention. Supports filter and conditioner, and calendar override.
Download 4003056-autotrol-460i-spec-sheet.pdf
13. Autotrol 460TC Timer
Electronic time clock timer with LED display, memory retention, and calendar override. Suitable for filter and conditioner applications.
Download 4003057-autotrol-460tc-spec-sheet.pdf
14. Autotrol 740 Timer
Economical electronic timer with large LCD display, super capacitor backup, and flexible regeneration scheduling (day/week/up to 99 days).
Download 4003060-autotrol-740-timer-spec-sheet.pdf
15. Autotrol 742 Timer
Time clock controller with LCD display, programmable cycle & salt setting, super capacitor backup, and remote regeneration start.
Download 4003061-autotrol-742-spec-sheet.pdf
16. Autotrol 760 Timer
Electronic meter control with LCD display, automatic backup, queued regeneration alerts, and data logging for flow rate & service history.
Download 4003062-autotrol-760-timer-spec-sheet.pdf
17. Autotrol 762 Timer
Metered control with LCD display, programmable cycle & salt dose, super capacitor backup, and historical data tracking.
Download 4003063-autotrol-762-spec-sheet.pdf
18. Autotrol LOGIX 764 Multi-Tank Residential Timer
Multi-tank controller with LCD display, queued regeneration, electronic programming, and power outage protection. Supports parallel, series, or twin alternating configurations.
Download 4003064-autotrol-764-logix-spec-sheet.pdf
19. Autotrol 360 Valve Manual Filter Valve
Manual filter valve for single tanks, fiber-reinforced polymer body, Duraflow flapper, and flow up to 21 GPM. Suitable for residential and commercial applications.
Download 43646-autotrol-360-spec-sheet.pdf
20. Autotrol 361 Valve Semi-Automatic Filter Valve
Semi-automatic filter valve with glass-filled Noryl body, Duralfow flapper, and continuous flow up to 21 GPM. Supports remote regeneration kit.
Download 43649-autotrol-361-spec-sheet.pdf
21. Autotrol 255 Residential Control Valve
Residential softener valve with glass-filled thermoplastic body, double backwash, optical sensor, and flow up to 15.5 GPM. Compatible with various timers (Easy-10, 460TC, 460I, 740, 760, 742, 762, 764).
Download 1018069-autotrol-255-spec-sheet.pdf
22. Autotrol 263 & 268 Residential Performance Control Valves
Residential softener/filter valves with glass-filled thermoplastic body, double backwash, optical sensor, and flow up to 25 GPM. Supports Easy-10, 460TC, 460i, 740, 760, 742, 762 timers.
Download 1223489-autotrol-263-268-spec-sheet.pdf
Pentair Autotrol Product Advantages
- Operational Efficiency: Salt and water savings, and precise regeneration cycles
- High Reliability: Memory retention, super capacitor backup, and corrosion/UV resistant construction
- Integration Flexibility: Compatible with various tank sizes, plumbing (NPT/BSP), and multi-tank systems
- Easy Maintenance: Easily accessible components, self-test, and clear troubleshooting
- Compliance: NSF/ANSI, UL, CE, RoHS certifications for safety and industry standards
Why Choose PT Watermart Perkasa?
As an authorized distributor of Pentair Autotrol, PT Watermart Perkasa provides the most complete product stock in Indonesia, ranging from valves, timers, retrofit kits, to spare parts and accessories. We ensure the availability of goods for project needs, OEM, and replacement of existing systems. Our technical team is ready to assist with design consultation, product selection, and after-sales support.
Most Autotrol products are available ready stock in our warehouse in Indonesia, so fast delivery and after-sales service are guaranteed.
Download All Pentair Autotrol Datasheets & Manuals
- Download 1017948-autotrol-460i-460tc-manual.pdf
- Download 1017972-autotrol-magnum-spec-sheet.pdf
- Download 1222945-autotrol-performa-400-service-manual.pdf
- Download 3000440-autotrol-255-performa-manual.pdf
- Download 3001093-autotrol-742-762-manual.pdf
- Download 3002943-255-logix-retrofit-kit.pdf
- Download 3019624-autotrol-logix-764-manual.pdf
- Download 3020015-autotrol-logix-764-owners-manual.pdf
- Download 4000570-autotrol-273-278-spec-sheet.pdf
- Download 4002013-auotrol-368-spec-sheet.pdf
- Download 4002833-autotrol-363-spec-sheet.pdf
- Download 4003056-autotrol-460i-spec-sheet.pdf
- Download 4003057-autotrol-460tc-spec-sheet.pdf
- Download 4003060-autotrol-740-timer-spec-sheet.pdf
- Download 4003061-autotrol-742-spec-sheet.pdf
- Download 4003062-autotrol-760-timer-spec-sheet.pdf
- Download 4003063-autotrol-762-spec-sheet.pdf
- Download 4003064-autotrol-764-logix-spec-sheet.pdf
- Download 43646-autotrol-360-spec-sheet.pdf
- Download 43649-autotrol-361-spec-sheet.pdf
- Download 1018069-autotrol-255-spec-sheet.pdf
- Download 1223489-autotrol-263-268-spec-sheet.pdf
Buyer questions about Pentair Autotrol
Are Autotrol filter and softener valves the same?
Not necessarily. A filter needs service and backwash sequencing, while a softener also needs brine draw, slow rinse, and refill. Match the valve body, controller, cam or flapper, injector, drain-flow control, and program to the approved duty.
When should I choose time-clock or metered-demand control?
Time-clock control can suit a stable operating schedule and load. Metered-demand control is more relevant when softener demand varies because the controller uses measured volume and reserve. Both still require correct resin capacity, salt dose, and calendar-override settings.
What information is needed for an Autotrol quotation?
Provide filter or softener duty, existing model and nameplate photographs, tank diameter, connection size, service and backwash flow, pressure, media or resin volume, power supply, demand pattern, and regeneration mode. For replacement work, include controller, valve-body, injector, and flow-control numbers.
Does valve selection alone guarantee water quality?
No. The valve controls flow and cycles. Results also depend on raw-water analysis, media or resin selection, capacity, backwash, regeneration, sanitation, commissioning, maintenance, and quality verification for the intended use.
Contact PT Watermart Perkasa
For a model review and quotation, send the system data through the Watermart contact page. If the project is still comparing control platforms, also review Pentair Fleck control valves and state the reason for the planned retrofit or standardisation.
PT Watermart Perkasa - Trusted Water Treatment Solutions for Industrial, Commercial, and Residential.